JP200 Jobber Plus+ Punch Press Control

Jobber Plus+

Price

$4695

Details

The Jobber Plus+ is a limited revolution punch press products offered by Metal Tech Controls. Metal Tech Controls unique press brake punch press devices can act as an interface between light curtains. In turn, these punch press products are designed to guard personnel working around moving machinery and increase safety in the workplace. The Jobber Plus+, press brake punch press device can be used to monitor the machine stopping time and the drive mechanism of the E-Cam for loss of motion. Installation of these press brake punch press device systems is easy to install with the help of our step by step installation and procedure guide.

Description

Features

  • Die Protection (8 programmable inputs)
  • Press Automation (8 programmable outputs)
  • Complete Clutch/BrakePress Control Resolver Based Electronic Cam Switch (E-Cam Included).
E-Cam 2012 Cam Switch Options and Pricing

Die Protection

Eight Programmable Inputs

Eight user programmable inputs are provided for die protection and other functions.

Ejected part detection input and any input 5 to 24 VDC positive sourcing or sinking, toggle, relay, proximity, inductive, infrared or contact closing to ground.

Simply select whether you want Top Stop or Emergency Stop, whether or not the input is ON during the programmed dwell or OFF. Enter the degree ON point and the degree OFF point.

Punch Press Control Jobber Plus+ Labels

Press Automation

Eight Programmable Inputs

Metal Tech Controls, punch press products such as the Jobber Plus+ offers eight programmable relay outputs to control any function. Drive part ejectors, press feeds, uncoilers and straightners, lubricators, choppers, indie tappers, toggles and just about any other punch press products automation feature you require!

Jobber Plus+ Punch Press Control labels press brake

Program one to come ON during a specified dwell time.

– Jobber Plus+

Program another to wait for a specified time to come ON and stay ON for a specified time.

labels for Jobber Plus+ Punch Press Control

Program a third one to count ‘x’ strokes of the machine and then come ON for a specified time.

press brake Jobber Plus+ Punch Press Control labels

Program a fourth in the same way as the others.


Press Brake Punch Press Device Control Features

  • Resolver Based Electronic Cam Switch
  • Time-Based Brake Monitoring
  • Plain English Diagnostics
  • Lost Motion Detection
  • Inch, Single & Continuous Operation
  • Continuous on Demand
  • Reverse Direction Detection (except in Inch Mode)
  • Micro Inch (timed jog for setup)
  • Top Stop Push Button
  • Emergency Stop Push Buttons (locking type)
  • Dual Palm Button or Foot Switch Selector Switch
  • Two Operator Station Inputs (user selectable)
  • Two Light Curtain Inputs
  • Light Curtain Muting on Up Stroke
  • Low Clutch/Brake Air Pressure Input
  • Low Counter Balance Air Pressure Input

Control Diagnostics

A diagnostic screen can be accessed to allow visual indication of an input changing state. If an input is ‘ON’ a ‘1’ will be displayed. If it is ‘OFF’ a ‘0’ will be displayed. By pressing buttons, activating switches or cycling the press, the status of the inputs can be determined making it easy to find faulty components.press brake punch press device, Jobber Plus+.

Plain English Error Messages

All errors that occur are displayed and a suggestion for remedy is offered.press brake punch press device, Jobber Plus+.

OSHA and ANSI Standards

All Systems Meet and/or Exceed OSHA 1910.217, ANSI B11.1, CSA and European Safety Standards.

metal tech controls labels for jobber
Jobber Plus label metal tech controls

Control Reliability

Twin microprocessors powered by their own independent power supplies. Both processors independently perform clutch/brake and input logic while simultaneously monitoring each other. Each processor powers an independent relay and monitors other relay to check opening and closing.

Relays have force-guided contacts. In the event of a relay failure, the press would be shut down instantly and the LCD will display “RELAY FAULT”. Relays are field replaceable.

If either processor fails, the control will issue a stop signal and prevent further strokes of the press until the fault is corrected. The fault will be displayed in plain English on the LCD.

All vital functions are stored in nonvolatile FLASH and battery-backed memory for maximum redundancy and reliability.